Multi-purpose clinical centrifuge ideal for the centrifugation of samples in clinical, chemistry, cytology, research and industrial laboratories. Speed can be set from 300 rpm to a max. of 6000 rpm/4300xg. Speed accuracy: ±20 rpm. Able to work with swing-out bucket and fixed angle rotors. Automatic rotor identification. Can work in continuous run or with a timer that can be set up to 99 min. Up to 9 procedures can be stored which makes the operation simplified. Delivers fast acceleration and deceleration (Acceleration: 9 seg / Breaking time: 10 seg) to ensure optimal separation. Maintenance-free brushless DC motor. Sound-alert function. Door interlock, over speed detector, automatic internal diagnosis. Dimensions: 445 x 579 x 269 mm. 200-240 V / 50-60 Hz.The instrument includes a stainless steel swing-out rotor, 4 positions (CCEN-A10-001) and supports and adapters for 100 ml, 85 ml, 50 ml, 15 ml and 3-7 ml tubes (CCEN-A11-004). The included CCEN-A10-001 rotor can be combined with the A11, A12, A13 and A14 supports and adapters in the table below. Rotors A15-A21 do not require supports and adapters. Warranty 2 years
# | SKU / Title | Price | |
---|---|---|---|
1 |
mnd-5000-71
|
(Not set) |
|
2 |
mnd-5000-72
|
(Not set) |
|
3 |
mnd-5000-73
|
(Not set) |
|
4 |
mnd-5000-74
|
(Not set) |
|
5 |
mnd-5000-75
|
(Not set) |
|
6 |
mnd-5000-76
|
(Not set) |
|
7 |
mnd-5000-77
|
(Not set) |
|
8 |
mnd-5000-78
|
(Not set) |
|
9 |
mnd-5000-79
|
(Not set) |
|
10 |
mnd-5000-80
|
(Not set) |
|
11 |
mnd-5000-81
|
(Not set) |
|
12 |
mnd-5000-82
|
(Not set) |
|
Multi-purpose clinical centrifuge ideal for the centrifugation of samples in clinical, chemistry, cytology, research and industrial laboratories. Speed can be set from 300 rpm to a max. of 6000 rpm/4300xg. Speed accuracy: ±20 rpm. Able to work with swing-out bucket and fixed angle rotors. Automatic rotor identification. Can work in continuous run or with a timer that can be set up to 99 min. Up to 9 procedures can be stored which makes the operation simplified. Delivers fast acceleration and deceleration (Acceleration: 9 seg / Breaking time: 10 seg) to ensure optimal separation. Maintenance-free brushless DC motor. Sound-alert function. Door interlock, over speed detector, automatic internal diagnosis. Dimensions: 445 x 579 x 269 mm. 200-240 V / 50-60 Hz.The instrument includes a stainless steel swing-out rotor, 4 positions (CCEN-A10-001) and supports and adapters for 100 ml, 85 ml, 50 ml, 15 ml and 3-7 ml tubes (CCEN-A11-004). The included CCEN-A10-001 rotor can be combined with the A11, A12, A13 and A14 supports and adapters in the table below. Rotors A15-A21 do not require supports and adapters. Warranty 2 years